La2a vu meter. 3 volts across the LED terminals.


  • La2a vu meter Skip to content (800) 421-7244. com Feb 26, 2016 · That means decreasing total meter resistance from ~~7. Buyer received it, 1 meter isn't working at all. VU Meter (4) This is a standard VU meter that displays either the amount of gain reduction, or output level, depending upon the setting of the Meter Function switch. 69" W x 2. Last night I put a new VU into my LA2A and that is exactly what happened. 20 seconds AL39 0. I just sold an La2a reissue. Replacement meter bezel for the UREI 1176LN, LA3A, LA4, and 1178 limiters The VU meter. Features and benefits. Prepare to be swept away by a sound that harkens back to the golden age of Find many great new & used options and get the best deals for ORIGINAL Vintage Beede VU Meter for Teletronix UREi LA2A LA-2A Limiter BLACK at the best online prices at eBay! Free shipping for many products! Oct 9, 2023 · When set to +10 or +4, the VU Meter indicates the output level in dB (when set to +4, a meter reading of 0 corresponds to an output level of +4 dB). UL. New Price $179 + $24. Universal audio La2a vu meter. It's a great time to upgrade your home music studio gear with the largest selection at eBay. Less than 25% the size and cost with 100% authentic tone. For example in an optical compressor like the LA2A, a light bulb electro luminescent light panel is lit up by the strength of the input audio, and the output of a photo sensitive cell next to it controls the amount of gain reduction. UTC A-33 -20 dB magnetic shield for Fairchild 670 / Urei Universal Audio LA2A. 9K Illumination: Dual LEDs vintage-white/yellowish Cut-Out: 54mm hole. Also the 1mA general-purpose meter will be much slower than a true VU meter. New Meter Bezel Mount For Modutec VU Meters For All UREI and UA 1176LN LA3 LA4 1178. A VU meter is slow by design, as is human hearing, which behaves more like a VU meter than a peak-level meter. 21 seconds Product – general description The Presentor Audio Level Range of Analog Panel Meters complements the proven and popular industrial series. This thing looks like the Vegas strip during operation, with four LED bars and two VU meters flashing all over the place. Daher gibt es das LA2A Plugin von vielen verschiedenen Herstellern. Specifications Page 8: Vu Meter Operation VU Meter Operation The VU Meter is used for both output level monitoring and gain reduction monitoring. The complete LA-2A family consists of three individual plug-ins. The LED's were working, but are no longer lighting up. - and second, because the plug doesn't give me a choice. Home Bulbs VU Meter Lamps Showing all 2 results Sorted by popularity. View similar gear from other sellers on Reverb. in GR mode the needle is just slammed to the right. The Teletronix LA-2A Studio Compressor puts the sounds of our legendary optical tube limiter at your feet, voiced to precisely match the original hand-wired hardware — with all the inspiring tone and classic feel on tap. This VU meter fits for many projects for example the LA2A compressor. Fast & Free shipping on many items! The meter is similar from specs and look to Sifam AL29WF meter and can be used as alternative or quality replacement meter. Mar 30, 2022 · Bought this LA-2A clone from Reverb. msg887257#msg887257 Jun 14, 2019 · Finally, but not least important is the looks. May 6, 2024 · LA-2A Plug-In Family. The VU meter is a seemingly simple electro-mechanical device that happens to be attached to a very complicated box, the Gyraf G24 Passive/Aggressive Compressor we wrote about before. The VU meter may also be switched to show the gain reduction or output level. Conventional vu meter 0. Back of panel mounting with accompanying bezel. Hard relay bypass when comp power off or switched to LA OFF. The state-of-the-art algorithms in the Teletronix LA-2A Leveler Collection take full advantage of modern CPU resources and the design sophistication and expertise gained since the introduction of the original LA-2A plug-in in 2001. Meter switchable Gain Reduction / LA OFF (meter led off) / VU by toggle switch; Electronic balanced input to handle extreme input levels without distortion. where VU meters come in to play. Specifically, the VU meter and pre-emphasis can be adjusted easily, as opposed to the vintage LA2A, which required a screw driver to adjust the same controls. 16 - 0. I have completely removed it from the patchbay and isolated it to see if it was something weird. Apr 1, 2024 · VU Meter. _____ The AudioScape Opto Comp is a meticulously crafted optical tube compressor that pays homage to a renowned compressor from the 1960s. This piece of gear has sold. May 22, 2024 · Find many great new & used options and get the best deals for (4) NEW VU Meter Bulbs - Universal Audio / Teletronix LA2A at the best online prices at eBay! Free shipping for many products! Jun 12, 2019 · My LED's in my VU meters appear to have burned out. Brand New 2x Audio Level VU Meter WF1029X for LA2A 3,00 € Discount +44,73 € La2a Stereo Case 1x V-Case Pro 2U 19" Enclosure Stereo Back-Panel +102,53 € Jul 15, 2003 · I’m thinking that maybe I can use one of my many compressors without engaging their parameters and just use the meter in a “pre” position to read the output. 14 - 0. Meter switch: controls the VU meter to either show gain reduction, output +4 dbu (todays studio standard) or +10 dbu Peak reduction controls the amount of gain reduction applied – even though the front panel layout suggests it comes behind the gain pot, this actually is the first pot the signal hits after entering the circuit Mar 13, 2015 · I still use VU's all the time - for internal processing, mostly because I'm used to that type of measuring in those certain pieces that used it originally; plugs like the 1176, LA2, Focusrite Red, the 670, etc. I would not try to read speech/music on such a sluggish needle. Replacement meter bezel for the UREI 1176LN, LA3A, LA4, and 1178 limiters price for 2 1970’s Modutec VU meter in good used condition from an Auditronics Recording Console. We’re glad that Warm Audio decided to make this minor design change. Inside the VU meter there are two LED wired in series. Menu. Search. Each variation has its own unique sonic characteristics. Steps:https://groupdiy. TASCAM 144 244 Portastudio Parts VU Meter Assy, Set of 4 TEAC 6055029000. I thought since it was a Triplite brand and looks like the standard Hi! I’m building an optical compressor guitar pedal and I have a spare small VU meter with a needle which I want to use as GR meter, just like on Teletronix LA2A - after switching the device needle should travel to “0” and lean back when some limiting occurs. Contact. Limit / Compress Switch Dec 24, 2012 · Same problem with one of my La3a reissues. 3 volts across the LED terminals. Used – Good. Page 9: Calibration Basic demonstration of how to calibrate your LA2A meter with T4B cell installed. Jul 9, 2013 · There’s a switch to choose between Compress (roughly a 4:1 ratio) and Limit (infinity ratio) mode. When the meter is dim, the plug-in is bypassed with the Meter Select switch or the host’s bypass switch. Fully analog signal path complete with transformers, tubes, and T4B. com. Neve 2254 Meter Cover Type 2 70s? Used – Excellent. applied, and the other one is connected to the VU meter to make it reflect the amount of gain-reduction. 18 seconds AL29 0. The LA2A embodies the spirit of classic craftsmanship, utilizing the renowned 12AX7/12BH7 signal tubes and 12AX7/6AQ5 sidechain tubes. price for 2 Anyone ever have a problem with a LA2A VU. Ive finally worked out a part number with Beede on the LA2A meter. Professionellen Tonschaffenden ist sicher bekannt das ein LA2A eigentlich in keinem seriösen Tonstudio fehlen sollte. Any Idea what would cause this? 4. However, I have to say that the small VU meter, while easy to read, isn't as attractive as the larger metering of the LA2A. If the signal is below the threshold, then the release will be faster. The VU meter displays the amount of gain reduction or the output level. The WF1029X meters suit for front- and rear-panel mounting and can be secure fixed with the inclusive bezel and scew tab terminals. Now, the Pultec is a plug I will fairly often insert set to zero, as it's got a really nice color just engaged with no EQ. The pro of using the filter/lag is it ensures equal attack/release times/curves, the down side is you need to figure out the actual time response yourself, which is easy to do by printing the signal to an audio track where you can At the heart of the original unit there is a photo-cell coupled with an opto-attenuator, which are faithfully reproduced into the Comp LA plug-in. should I be connecting my mic into the ISA One and going out via send (ISA ONE) to the input of LA2A and taking LA2A output back into the return of the ISA One? In option 1, I can clearly hear the gain impact, but doesn't look like the compression is really working--the VU meter remains stuck no matter how I toggle the peak reduction. Easy to copy the scale considering keith has provided a scan of one on Kruz's site. See full list on media. 13 - 0. . Note: When set to Output, the meter displays the wet, processed signal level only. The LED bars and VU meters also share much of the same functionality, making the need for both a bit redundant. Each LA-2A model features consistent controls for peak reduction, gain, VU Meter, compression/limit, emphasis, High-frequency filter, and on/power switch, ensuring familiarity and ease of use across units. Tascam 122 MKII, MKIII, 112 MKII, 112R MKII VU Meter Lamp/Bulb VU Meter Operation The VU Meter is used for both output level monitoring and gain reduction monitoring. These are the same dimensions as the Sifam replacement VU meters for Urei LA2A compressor/limiters (3. Large 32mm chicken head input level control for easy setting of compression level. Dec 14, 2017 · Large 34mm white LED backlight GR/VU meter. Does that work? My options At the moment For vu meters (incorporated into compressors) would be psp Vintage Warmer, or waves La2a or the 1176. High quality LA-2A tube optical compressor limiter. The photo-cell provides a very natural dual-stage release which results in a very characteristic compression response, more transparent than that of other compressors: Nov 15, 2009 · Or 2. These meticulously chosen components breathe life into your audio, infusing it with warmth, character, and unmistakable vintage charm. Users may notice that it takes quite some time for the meter to return to 0 VU (no compression) after a long period of heavy compression. Faithful recreation of the original vintage La-2a circuit. $129. Meter stopped doing GR after several weeks after warranty expired. How The LA-2A Works May 3, 2003 · The meter is a VU meter, so it's averaging, and you can assume that set to input or output, you're passing more peak level than it's showing, and in GR, you're getting more compression on the transients than it's showing. Originally C$750, now C$300 (60% savings) La-2a VU meters. 95 Shipping. LOL. We’ve meticulously integrated cutting-edge digital technology with classic analog equipment like the Teletronix LA-2A and Warm Audio WA2A compressors. The VU meter may also be switched to show gain reduction or output level. It sounds like it should by the values on the knobs but the metering is useless as it never changes. This complexity means it's easy to get lost and keeping your eyes on the meters becomes an important aspect of work with the G24. 5 to 5 seconds for full release, depending on the previous program material. Hand wired point to point with top shelf components and AMI transformers replicas of the original vintage UTC A-10 and A-24 transformers. Sep 3, 2021 · That will get you super close to the ballistics of a VU meter, depending on the curve of the attack/release. Bisher nützte ich das CLA-2A von Waves mit dem man auch gute Resultate erzielen kann. The range offers a performance not significantly different from full specification VU meters to meet today's audio market requirement for quality at affordable prices. If I can not find a replacement lamp or led that is 6v AC that will fit my Hairball VU, is there any possible way to connect my DC leds or lamps to the 6v AC using a Jun 30, 2003 · Good news for anyone doing the LA2A. In retrospect, it would have been fine just to install a trimmer on the circuit board. I packed it great for shipping. The mode being displayed depends upon the setting of the Meter Select switch. 6k resistor) Internal Resistance: 3. My Hairball VU meters has a 5v led or 12v lamp that is DC. Oct 27, 2023 · Universal Audio UAFX Teletronix LA-2A Pedal, Builder’s Notes. We have made no compromise in parts which ensures you get the best sounding LA-2A money can buy. Now the special compression character of an Opto compressor is based on the timeframe all of this happens within. 17 - 0. Great deals on Vu Meter In Pro Audio Parts & Accessories. However, there’s a subtle detail on the back panel: an R37 pre-emphasis screw… Oct 24, 2016 · If compression is heavy or the signal is above the threshold for a long duration, then the release will be slower. They will sell the exact same meter minus the Teletronix logo on the meter scale, correct sensitivity, tolerance and scale deflection. Me thinks UA is using crap meters these days? The Presentor Audio Level range of analogue panel meters complements the proven and popular industrial series. Height . Showcase. Panel controls: Gain (input level), peak reduction, and meter selector switch; Meter: dB gain reduction and dB output; Power requirements: 115/230 volts, 50–60 cycles, 35 watts; Tube complement: (2) 12AX7A (1) 12BH7A (1) 6AQ5; Fuse: 3AG, 3/8 amp slow blow for 115V; 3AG 15/100 amp slow blow for 230V PLEASE ALLOW APPROXIMATELY 3 WEEKS FOR SHIPPING. 15 seconds AL19 0. The middle setting is for gain reduction, and the meter reads the amount of compression in dB. Vintage-Meters VM2103 is a nice looking vu meter with a scale of -20 to +3dB. If I stick an led across the terminals, it lights up, but quickly gets very hot. Jun 3, 2004 · Hello, I remember a long time ago a discussion on the BLOO LA2A thread about if you did not use a "Real" VU on the LA2A it might load down your output. However, there’s a subtle detail on the back panel: an R37 pre-emphasis screw… Meter These four pushbutton switches (to the right of the VU Meter) determine the mode of the VU Meter, and whether the plug-in is enabled. Haven't had the time to fix it yet. Im getting 6. A VU meter’s relatively slow attack (300 ms from infinity to 0 dB VU) averages out many of the short peaks, resulting in a more real-world expression of dynamics. Industrial Applications; Analogue compressors are built with different designs or technologies to achieve their compression effects. Manufacturing. We used a zener diode rather than the original neon bulb for this circuit so there’s very little drift. Worked perfectly for me. Specifications: Model: VM2103 0dB Configuration: 0dB at 1. 9K + meter resistance) to around 750 Ohms. When used to monitor the output level, the user may choose either +4 dB or +10 dB settings. 5K (3. The average attack time is 10 milliseconds, [ 5 ] while the release time is about 60 ms for 50% release and 0. Incandescent Axial Lead bulbs are used in audio equipment, VU meters and more. When you crank up the volume maximum in Protools, put the studio monitors maximum and put the gain on maximum on the La2a, you can hear the oscillating noise very well. and sharing how to calibrate your VU meter to 0dB for gain reduction. 85" H) sold for $210/ea but are larger than the original Modutec meters installed in the 1176, LA-3 This bulb is a direct replacement for the Universal Audio/Teletronix LA-2A VU meter bulb. Apr 17, 2022 · Shortly after the LA-2 was created which was where the T4A optical attenuator first appeared, along with design changes showing off a larger VU meter, along with swapping out the multi-position toggle switch in favor of a rotary switch. Apr 6, 2006 · One of the design modifications that really helped with usability are the knobs on the back of the unit. 228V (trough an external 3. It works fine in every setting except gain reduction. Using the DI input with an electric guitar, I found the ability to control the amount of front-end gain was very effective in adding character and bite to an otherwise lifeless pickup. Show sidebar Filters. Super excited about this unit, this addition to my Dec 3, 2024 · -I think ART went a little overboard with the LED's and VU meters. Then again, who would really want to see an LED meter on an LA2A or 1176 Jul 9, 2013 · There’s a switch to choose between Compress (roughly a 4:1 ratio) and Limit (infinity ratio) mode. At Digalog Audio, our modified hardware is designed to revolutionize the way you interact with your beloved analog gear. Brand New. I was considering buying an La2a but I am a little hesitant because of this noise. We went the extra mile to source the original LA-2 VU meter, knobs and screws in a beautiful raw brushed aluminum finish including the rack ears famously known as the “silver face”. And finally, it also has a three-way switch to select whether the VU-meter displays the gain reduction or the output level (+4 or +10). D-LA2A zero set; the pots are for zeroing the VU meter when no gain reduction is occurring. When set to +8 or +4, the VU Meter indicates the output level in dB; when set to +4, a meter reading of 0 corresponds to an output Inside the sealed canister are an electro-luminescent panel, very much like that found on a “nite-lite”, and two photo resistor cells pressed up against the electro-luminescent panel; one that controls gain reduction, which I will soon explain, and one to control the VU meter when in gain reduction mode. This is a heavy load on a 600r output. Filter by. The release behavior of the LA2A is even more funny than the attack behavior. Compatible replacement meter for the Urei 1178 /1176 Studio compressor. Mar 16, 2015 · The LA-2A has simple controls: a Peak-Reduction knob controls the gain of the side-chain circuit, and therefore, the gain reduction; a Gain Control for make-up gain; and a Limit/Compress switch which alter the compression ratio. Sep 5, 2009 · Very low, you can't really hear it, but you can see it on the digital vu meters on protools. And bad distortion because of the diodes. uaudio. View similar Apr 6, 2009 · My Drips La2a PCB board Version 3 outputs 6v AC for the lamp section. When set to GR, the VU Meter indicates the Gain Reduction level in dB. com/index. $100. That compressor was highly regarded for its musicality, smooth compression, and distinctive tone achieved by using an incandescent light bulb and optical sensor to control dynamic processing, and passing au The Doc Lloyd DLA-2A Leveling Amplifier is a meticulous recreation of an iconic studio compressor, now available as a pedal directly compatible with guitar and bass input signals. php?topic=3278. zczv jfdwsq zccao vjphp roki bpdetwe qxghjp ihptt nphz ghwn